Broadband UV to mid-IR windows. CaF₂ transmission 130-7800nm. Custom sizes available. Request a quote.
When specifying this product, these parameters most directly impact performance and cost:
| Material | Calcium Fluoride (CaF₂) |
|---|---|
| Transmission | 130 nm - 7800 nm |
| Diameter | 5-100 mm |
| Thickness | 1-30 mm |
| Surface Quality | 20-10 / 10-5 |
| Flatness | λ/4 @ 632.8nm |
| Refractive Index | 1.43 @ 632.8nm (low) |
| CTE | 18.85 ppm/K |
Parameter Reference Guide
Typical Standard capability — available as shown
Available Alternative options exist — request quotation
Custom Per your drawing — quote after review
Subject to Review Depends on project specifics
Calcium Fluoride Optical Windows are fabricated from Calcium Fluoride optical material, providing specialized transmission and mechanical properties for demanding optical applications.
PhotonEdge sources Calcium Fluoride windows from certified material suppliers and coordinates precision manufacturing through our optical manufacturing network.
Select the optimal substrate material based on your wavelength, environment, and budget requirements.
| Material | Transmission | Key Advantage | Considerations |
|---|---|---|---|
| N-BK7 | VIS / NIR (350-2000nm) | Low cost, good visible performance | No UV transmission below 350nm |
| UV Fused Silica | UV / VIS / NIR (185-2100nm) | Best UV transmission, low CTE, no solarization | Premium cost |
| Sapphire | UV / VIS / NIR (150-5500nm) | Extreme hardness (9H), scratch resistant | Birefringent, higher Fresnel loss |
| CaF₂ | UV / VIS / IR (130-7800nm) | Broadest transmission, low index, excellent UV | Fragile, moisture sensitive |
Not sure which material to choose?
Ask AI Optical EngineerAR for deep UV wavelengths.
Typical use: UV laser and spectroscopy
Broadband AR from 200nm to 6µm.
Typical use: Multi-band systems
Raw CaF₂. ~3.5% per surface (low n advantage).
Typical use: Non-critical
To select the right coating, please provide: (1) Operating wavelength, (2) Angle of incidence, (3) Required transmission or reflectivity, (4) Laser power density (if applicable), (5) Operating environment.
Key factors to evaluate when specifying this optical component for your system.
Calcium Fluoride has specific transmission characteristics. Verify compatibility with your operating wavelength.
Specify based on application: 40-20 for general, 20-10 for precision, 10-5 for laser-grade.
λ/4 standard. Tighter specifications available for wavefront-critical systems.
Consider thermal, chemical, and mechanical environment when selecting window material.
Beam conditioning, wavelength selection, and signal extraction in spectrometers.
Laser line filtering, beam shaping, and optical filtering.
Excitation and emission filtering for fluorescence microscopy.
Optical measurement setups and spectroscopic analysis.
| Capability | Standard | Precision | Project-Specific |
|---|---|---|---|
| Surface Quality | 40-20 | 20-10 | 10-5 or tighter |
| Flatness | λ/4 | λ/10 | λ/20+ |
| Dimensional Tol. | ±0.05mm | ±0.01mm | ±0.005mm |
| Centration | ≤3 arc-min | ≤1 arc-min | ≤30 arc-sec |
Actual capability depends on material, geometry and coating. Final specifications confirmed through engineering review.
PhotonEdge supports optical component sourcing, engineering review, and qualified manufacturing through our optical manufacturing network. We coordinate production, coating, and inspection to deliver components that meet your specifications.
Diameter, thickness, focal length verified per specification
Scratch-dig inspection under calibrated illumination
Spectrophotometric measurement of transmission/reflectance
Inspection documentation available according to project requirements. Certificates of Conformance, material test reports, and coating curves can be provided.
| Document | Purpose |
|---|---|
| Inspection Report | Confirms optical and mechanical specifications |
| Material Certificate | Confirms substrate material and grade |
| Coating Report | Confirms coating performance and wavelength range |
| Certificate of Conformity | Confirms conformity to agreed requirements |
| Dimensional Report | Confirms mechanical dimensions and tolerances |
Documentation provided according to agreed project requirements.
The following documentation is available upon request for qualified engineering projects:
CAD & dimensional specs per your requirements
Material properties, transmission curves & certificates
Spectrophotometric measurement data
Surface quality, flatness, centration & dimensional data
CoC with full traceability per project requirements
Application-specific specification documentation
Documentation availability depends on project scope and order quantity. Request details during RFQ.
Contact us for exact pricing based on your specifications.
Specification Parameters
Typical Specifications shown on this page are standard capabilities. Available Options include alternative materials and coatings. Custom Specifications are available per your drawing. Requirements beyond standard capability are marked Subject to Engineering Review.
Standard diameters range from 5mm to 100mm with thicknesses from 1mm to 50mm. Larger sizes and custom shapes are available upon request.
Most optical window materials are compatible with vacuum environments. Fused silica and sapphire have very low outgassing characteristics.
For laser applications, 10-5 is recommended. For general-purpose windows, 20-10 is acceptable and more economical.
Yes. Circular, rectangular, square, and custom shapes are available. Provide your drawing or dimensional requirements for a quotation.
λ/10 is standard for precision applications. For wavefront-critical systems, λ/20 or tighter is available. Note that tighter flatness directly affects cost.
Provide: material, diameter/shape, thickness, wavelength, surface quality, flatness, coating requirements, and quantity.
Yes. CaF₂ is relatively soft (3 Mohs) and cleaves along crystal planes. Handle with care.
Slightly. Store in dry conditions. Not recommended for prolonged humid environments without protective coating.
Describe your optical system and our AI Optical Engineer will help identify the right specifications, materials, and coatings for your application.
Ask AI Optical EngineerTo help us provide an accurate quotation, please prepare the following information. Not all fields are required — send what you have, and our engineering team can help identify missing parameters.
Not sure about some specifications? Send what you have — our engineering team will help identify the missing parameters and recommend appropriate values for your application.
Provide your requirements and our engineering team will respond within 1 business day with a detailed quotation.
Upload your drawing or specifications. Our engineering team will review and respond within 1 business day.